Sampling was carried out at Site B on 26-28 September 2002. Samples were collected from the swarf baghouse stack, wheel melt baghouse and furnace 2 discharges to determine the concentration and mass emission of PCDD and PCDF present in the gases discharged to the atmosphere.

4.1 Introduction

The sample point was located in the stack exiting from the swarf baghouse stack. The sample point is more than 8 diameters downstream and approximately 3 diameters upstream from any disturbance to flow.

Two sample points had been installed for sampling particulate. However, these were not suitable for dioxin sampling due to restricted access. One additional port was added for dioxin sampling.

Details of the sampling times and stack dimensions are:

  • Sampling time: 8:57-12:57
  • Stack dimensions: 0.7 metre diameter circular duct.

4.2 Results

4.2.1 Swarf drier

Table 4.1: Stack gas conditions at the swarf baghouse stack sampling point

CO2 Temperature(°C) Moisture(%) Velocity(m/s) Flow rate
(%, wet) (%, dry) (m3/s) (m3/s, 0°C, 1 Atm, dry)

1.8

1.8

94.0

2.4

9.3

3.6

2.6

Table 4.2: Results of isokinicity for swarf baghouse stack

Sample Actual sample volume
(m3, 0°C, 1 Atm, dry)
Calculated sample volume
(m3, 0°C, 1 Atm, dry)
Isokinicity
(%)

1

3.8996

3.7368

104%

All samples are within the required isokinicity range of 100 ± 10%

Table 4.3: Average combustion gas results for swarf baghouse stack

CO
(mg/m3)
SO2
(mg/m3)
NO
(mg/m3)
O2
(%)
NO2
(mg/m3)

< 11

< 25

17.7

18.7

<9

The weight of scrap metal melted during this sample was 4 tonnes.

Table 4.4: Summary results from swarf baghouse stack

    Concentration
(ng/m3)
Emission
(ng/hr)
Emission
(ng/tonne)

Sum of PCDD and PCDF congeners

Excluding LOD values

1.64

15,315

15,315

Including half LOD values

1.64

15,315

15,315

Including LOD values

1.64

15,315

15,315

Total I-TEQ

Excluding LOD values

0.0199

186

186

Including half LOD values

0.0210

196

196

Including LOD values

0.0222

207

207

Total WHO-TEQ

Excluding LOD values

0.0203

189

189

Including half LOD values

0.0214

200

200

Including LOD values

0.0226

211

211

Table 4.5: Results from swarf baghouse stack (individual congeners)

View results from swarf baghouse stack (individual congeners) (large table)

4.2.2 Wheel melt furnace

The sample point was located in the stack exiting from the wheel melt baghouse stack. The sample point is more than 8 diameters downstream and approximately 3 diameters upstream from any disturbance to flow.

Two sample points had been installed for sampling particulate. However, these were not suitable for dioxin sampling due to restricted access. One additional port was added for dioxin sampling.

Details of the sampling date, times and stack dimensions are:

  • Sample date and time: 27 September 2002, 11:29-15:32
  • Stack dimensions: 0.60 metre diameter circular duct.

Table 4.6: Particulate emissions from wheel melt baghouse stack

Sample Sample mass
(g)
Particulate emissions
(mg/m3, dry, 0°C, 1 Atm) (kg/h)

1

0.0001

0.02

0.00021

Note: The sample mass is below the limit of detection.

Table 4.7: Average stack gas conditions at the wheel melt baghouse stack sampling point

CO2 Temperature(°C) Moisture(%) Velocity(m/s) Flow rate
(%, wet) (%, dry) (m3/s) (m3/s, 0°C, 1 Atm, dry)

<0.5

<0.5

63.0

0.7

11.0

3.5

2.8

 

Table 4.8: Results of isokinicity for wheel melt baghouse stack

Sample Actual sample volume
(m3, 0°C, 1 Atm, dry)
Calculated sample volume
(m3, 0°C, 1 Atm, dry)
Isokinicity
(%)

1

4.7979

5.0816

94

All samples are within the required isokinicity range of 100 ± 10%.

Table 4.9: Combustion gas results

CO
(mg/m3)
SO2
(mg/m3)
NO
(mg/m3)
O2
(%)
NO2
(mg/m3)

< 11

< 25

< 12

21.1

<9

The weight of scrap metal melted during this sample was 5.487 tonnes.

Table 4.10: Summary results from wheel melt baghouse stack

    Concentration
(ng/m3)
Emission
(ng/hr)
Emission
(ng/tonne)

Sum of PCDD and PCDF congeners

Excluding LOD values

0.00188

19.2

14.0

Including half LOD values

0.0132

136

99.0

Including LOD values

0.0246

252

184

Total I-TEQ

Excluding LOD values

0

0

0

Including half LOD values

0.000491

5.03

3.67

Including LOD values

0.000981

10.1

7.34

Total WHO-TEQ

Excluding LOD values

0

0

0

Including half LOD values

0.000588

6.04

4.40

Including LOD values

0.00118

12.1

8.80

 

Table 4.11: Results from wheel melt baghouse stack (individual congeners)

View results from wheel melt baghouse stack (individual congeners) (large table)

4.2.3 Furnace 2

One sample point was located in a vertical section of stack approximately 4 diameters downstream and more than 4 diameters upstream from a disturbance to flow.

Details of the sampling date, times and stack dimensions are:

  • Sample date and time: 26 September 2002, 11:04-15:58
  • Stack dimensions: 1.43 metre diameter circular duct.

Table 4.12: Particulate emissions from furnace 2

Sample Sample mass
(g)
Particulate emissions
(mg/m3, dry, 0°C, 1 Atm) mg/m3 (dry, 0°C, 12% CO2) (kg/h)

1

0.0020

0.67

5.7

0.017

Table 4.13: Average stack gas conditions at the furnace 2 sampling point

CO2 Temperature(°C) Moisture(%) Velocity(m/s) Flow rate
(%, wet) (%, dry) (m3/s) (m3/s, 0°C, 1 Atm, dry)

1.4

1.4

255

2.9

8.7

14.1

7.1

 

Table 4.14: Results of isokinicity for furnace 2

Sample Actual sample volume
(m3, 0°C, 1 Atm, dry)
Calculated sample volume
(m3, 0°C, 1 Atm, dry)
Isokinicity
(%)

1

2.9946

3.2262

93

All samples are within the required isokinicity range of 100 ± 10%.

Table 4.15: Average combustion gas results for furnace 2

CO
(mg/m3)
SO2
(mg/m3)
NO
(mg/m3)
O2
(%)
NO2
(mg/m3)

< 11

< 25

23.9

19.0

<9

The weight of scrap metal melted during this sample was 1.952 tonnes.

Table 4.16: Summary results from induction furnace 2

    Concentration
(ng/m3)
Concentration
(ng/m3 11% O2)
Emission
(ng/hr)
Emission
(ng/tonne)

Sum of PCDD and PCDF congeners

Excluding LOD values

0.00334

0.017

84.9

198

Including half LOD values

0.0172

0.086

437

1019

Including LOD values

0.0311

0.16

790

1841

Total I-TEQ

Excluding LOD values

0

0

0

0

Including half LOD values

0.00100

0.0050

25.3

59.0

Including LOD values

0.00199

0.010

50.7

118

Total WHO-TEQ

Excluding LOD values

0

0

0

0

Including half LOD values

0.00107

0.0054

27.3

63.6

Including LOD values

0.00215

0.011

54.5

127

Table 4.17: Results from induction furnace 2 (individual congeners)

View results from induction furnace 2 (individual congeners) (large table)

See more on...